The HJ-DYZ-600 intelligent high-frequency switch-mode power system comprises a cabinet, AC distribution, rectifier modules (up to 12 fully configured), a monitoring module, and DC distribution. It offers comprehensive battery management-including low-voltage protection and optional load disconnect-plus temperature compensation, automatic voltage regulation, stepless current limiting, capacity calculation, online battery testing, and sleep energy-saving. Networked design with RS232/RS485 and dry-contact ports enables flexible networking, remote monitoring, and unattended operation, with full AC/DC surge protection and complete fault protection/alarm functions.
Enviar mensaxe Obter prezo
| Parámetros ambientais | Condicións de funcionamento | Condicións de transporte | Condicións de almacenamento | Normas aplicables | Observacións | |||
| categoría | Parámetro | Unidade | ||||||
| Condicións climáticas | temperatura | Baixa temperatura | ℃ | -33 | -40 | -40 | YD/T 1058-2000 Cláusulas 4.1.1 e 4.1.2 | Arranque a plena carga a −40 ℃; redución lineal do 20 % de +55 a +65 ℃. |
| Alta temperatura | ℃ | 65 | 70 | 70 | ||||
| Cambio de temperatura | ℃/min | / | 1 | / | ETS 300 019-2-2 T2.3 | |||
| Temperatura ambiente | ℃ | -33-65 | Temperatura de funcionamento extrema a plena carga | |||||
| A temperatura de almacenamento | ℃ | -40-70 | ||||||
| Humidade | Humidade relativa do aire | % | 5-90 | 90 (40 ± 2 ℃) | / | Cláusula 4.1.3 do YD/T 1058-2000 | Short-term test: 0-95%, max 95%, non-condensing | |
| Condensación | Si non | Non | Non | si | ||||
| Presión atmosférica | Baixa presión | kPa | 86 | 70 | 70 | Cláusula 4.1.4 do YD/T 1058-2000 | Só probas de módulos | |
| Presión alta | kPa | 106 | 106 | 106 | ||||
| Altitude | m | ≤ 4000 | Por riba dos 2000 m, reducir a potencia 0.5 ℃ por cada 100 m adicionais | |||||
Nota: As especificacións están suxeitas a cambios sen previo aviso para mellorar o produto. Ficha técnica
Fully digital interleaved PFC innovative control with limited bipolar ZVS full-bridge topology, current-doubler rectifier topology, and dual MCUs for fully digital monitoring
Rectifiers use PFC so AC input current matches the voltage waveform and phase; high system efficiency saves energy and reduces OPEX
High-frequency PWM conversion reduces switching losses and EMI, allowing installation inside switching equipment rooms
Intelligent battery management with continuously settable equalization/float voltages and charge current limits via controller or remote system; supports float, equalization, and battery testing
Equipotential design across the cabinet improves EMC and lightning protection
É axeitado para varios escenarios de consumo de enerxía, como edificios residenciais e edificios de oficinas comerciais.